High Voltage 3Phase Hybrid Inverter GSL-10/ 12/ 15KHV-3PH

An on-grid inverter’s main job is to convert DC power generated from the PV array into usable AC power. Hybrid inverters go a step further and work with batteries to store excess power as well. In the developing world, hybrid inverters are more of a necessity to compensate for weak or intermittent grids or a lack of grid electricity all together.

Category:
Description
Model GSL-10KHV-3PH GSL-15KHV-3PH GSL-20KHV-3PH
Battery Input Data
Battery Type Li-Ion
Battery Voltage Range (V) 160~700
Max.Charging Current (A) 37
Max.Discharging Current (A) 37
Number of Battery Input 1
Charging Strategy for Li-on Battery Self-adaption to BMS
PV String Input Data
Max.DC Input Power (W) 13000 19500 26000
Max.DC Input Voltage (V) 1000
Start-up voltage (V) 180
MPPT Range (V) 150-800
Full Load DC Voltage Range (V) 325-850 420-850 500-850
Rated DC Input Voltage (V) 600
PV Input Current (A) 20+20 26+20 26+26
Max. PV I SC (A) 30+30 39+30 39+39
No.of MPPT Trackers 2
No.of Strings Per MPPT Trackers 1 2+1 2
AC Output Data
Rated AC Output and UPS Power (W) 10000 15000 20000
Max. AC Output Power (W) 11000 16500 22000
AC Output Rated Current (A) 15.2/14.5 22.8/21.8 30.4/29
Max. AC Output Rated Current (A) 16.7/16 25/24 33.4/31.9
Max. Three-phase Unbalanced Output Current (A) 22 30 35
Max. Continuous AC Passthrough (A) 40 80
Peak Power (off-grid) 1.5 time of rated power, 10 S
Generator input/Smart load /AC couple current (A) 15.2/40/15.2 22.8/80/22.8 30.4/80/30.4
Power Factor 0.8 leading to 0.8 lagging
Output Frequency and Voltage 50/60Hz; 3L/N/PE 220/380, 230/400Vac
Grid Type Three Phase
DC injection current (mA) <0.5%1n
Efficiency
Max. Efficiency 97.60%
Euro Efficiency 97.00%
MPPT Efficiency 99.90%
Protection
Integrated PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection, Surge protection
Output Over Voltage Protection DC Type II/AC Type III
Certifications and Standards
Grid Regulation VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1, G98, G99, C10-11, UNE217002,  NBR16149/NBR16150
Safety EMC / Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
General Data
Operating Temperature Range(℃) -25~60℃,>45℃ Derating
Cooling Smart cooling
Noise (dB)  <45
Communication with BMS RS485;CAN
Weight (kg) 30.5
Size (W*H*D) 408×638×237mm
Degree IP65
Installation Style Wall-mounted
Warranty 5 years