High Voltage 3Phase Hybrid Inverter GSL-29.9 30 40 50KHV-3PH

An on-grid inverter’s main job is to convert DC power generated from the PV array into usable AC power. Hybrid inverters go a step further and work with batteries to store excess power as well. In the developing world, hybrid inverters are more of a necessity to compensate for weak or intermittent grids or a lack of grid electricity altogether.

Category:
Description
Model GSL-29.9KHV-3PH GSL-30KHV-3PH GSL-35KHV-3PH GSL-40KHV-3PH GSL-50KGV-3PH
Battery Input Data
Battery Type Li-Ion
Battery Voltage Range (V) 160~800
Max.Charging Current (A) 50+50
Max.Discharging Current (A) 50+50
Number of Battery Input 2
Charging Strategy for Li-on Battery Self-adaption to BMS
PV String Input Data
Max. PV Access Power (W) 59800 60000 70000 80000 100000
Max. PV Input Power (W) 47840 48000 56000 64000 80000
Max. PV Input Voltage (V) 1000
Start-up voltage (V) 180
MPPT Voltage Range (V) 150-850
Rated PV Input Voltage (V)
600
Max. Operating PV Input Current (A) 36+36+36 36+36+36+36
Max. Input Short-Circuit Current (A) 55+55+55 55+55+55+55
No.of MPPT Trackers/ 

No.of String MPP Tracker

3/2+2+2 4/2+2+2+2
AC Input/Output Data
Rated AC Input/Output Active Power (W) 29900 30000 35000 40000 50000
Max. AC Input/Output Apparent Power (VA) 29900 33000 38500 44000 55000
Rated AC Input/Output Current (A)
45.4/43.4 45.5/43.5 53.1/50.8 60.7/58 75.8/72.5
Max. AC Input/Output Current (A)
45.4/43.4 50/47.9 58.4/55.8 66.7/63.8 83.4/79.8
Max. Continuous AC Passthrough (grid to load) (A)
200
Peak Power (off grid) (W) 1.5 time of rated power, 10 S
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/380V, 230/400V 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form 3L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Component of Grid <0.5% In
Efficiency
Max. Efficiency 97.60%
Euro Efficiency 97.00%
MPPT Efficiency >99.00%
Equipment Protection
Integrated DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485, RS232, CAN
Monitor Mode
GPRS/WIFI/Bluetooth/4G/LAN(optional)
General Data
Operating Temperature Range(℃) -40~60℃, >45℃ derating
Permissible Ambient Humidity 0-100%
Permissible Altitude 2000m
Noise ≤65 dB(A)
Ingress Protection(IP) Rating IP65
Inverter Topolog Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 527×894×294 (Excluding Connectors and Brackets)
Weight (kg) 80
Type of Cooling Intelligent Air Cooling
Warranty 5 Years/10 Years

  the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2